|
Requirement :
|
Provision of Otm Accommodation for Nursing Offr Mess at Mh Gwalior Under Ge, Surface Excavation Not Exceeding 30 Cm Deep and Averaging 15cm Deep and Getting Out in Hard/dense Soil Complete All as Specified and Directed. , Excavating Over Areas, N Exc 1.5 M Deep and Getting Out in Hard/dense Soil Complete All as Specified and Directed. , Removal Excavated Material (soil) Exc 250m But N Exc 500m and Depositing Where Directed at a Level N Exc 1.5 M Above the Starting Point Complete All as Specified and Directed. , Dismantling of Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness in Roof Covering Complete All as Specified and Directed. , Dismantling of Asbestos Cement (corrugated, Semicorrugated, Etc.) Sheets in Roof Coverings Complete All as Specified and Directed. , Dismantling Wrought Iron Or Mild Steel Work of Any Description Complete All as Specified and Directed. , Demolition of Brickwork Or Stone/boulder Masonry Built in Cement Or Cement Lime Mortar Including All Quoins, Arches, Pillars Etc. and Unserviceable Brick/debaris Dispose Off Complete All as Specified and Directed. , Dismantling Boarding/pelmet Etc in Any Description, Fixed in Any Position with Nails Complete All as Specified and Directed. , Dismantling Timber Scantling (unframed Work) in Fillets, Rails, Posts, Rafters, Purlins, Etc Under 40 Sqcm in Section, in Any Position Complete All as Specified and Directed. , Dismantling Wall & Ceiling Boards (fibre, Pulp, Insulation, Etc.) Or Insulation Boards/slabs/ Blankets, Any Thickness, Incl Cover Fillets/grid Frame Work Complete All as Specified and Directed. , Taking Down Chowkats Or Frames with Shutters (without Taking Off Shutter From the Frame) N. Exc. 1.50 Sqm Each and Removing From Site Complete All as Specified and Directed. , Taking Down Chowkats Or Frames with Shutters (without Taking Off Shutter From the Frame) Exc. 1.50 Sqm But N. Exc. 4 Sqm Each and Removing From Site Complete All as Specified and Directed. , Demolition of Reinforced Cement Concrete ( Reinforcement Cut as Reqd to Facilitate Demolition) in Shelves and Similar Suspended Work N.exc 15cm Thickness Below Or Above Ground Level and Removing Rubbish From Site Complete All as Specified and Directed. , Demolition of Cement Concrete in Ground Floors and Pavings N.exc 15cm Thickness (below Or Above Ground Level) Complete All as Specified and Directed. , Demolition of Cement Concrete in Ground Floors and Pavings Exc 15cm Thickness (below Or Above Ground Level) Complete All as Specified and Directed. , Dismantling Stone Slabs & Tiles of Any Description Or Thickness in Floors, Aprons Etc Laid Bedded and Pointed in Any Mortar Complete All as Specified and Directed. , Taking Down Old Bib Taps, Stop Cocks, Pillar Taps Etc of Cast Copper Alloy, 15mm Bore and Removing From Site Complete All as Specified and Directed. , Taking Down Old Pvc Connections of Any Description All as Specified and Directed. , Taking Down Old Wash Hand Basin of Any Description Incl Brackets & Waste Pipe Etc All as Specified and Directed. , Dismantling Old Pvc L/l Flushing Cistern with Flush Pipe, of Any Capacity Incl All Fixing Arrangements Etc All as Specified and Directed. , Taking Down Old Looking Mirror of Any Description All as Specified and Directed. , Taking Down Old Towel Rail/towel Ring Or Soap Dish of Any Description All as Specified and Directed. , Dismantling Old Pvc Water Storage Tanks of 500 Ltr Capacity and Removing From Site All as Specified and Directed. , Taking Up Or Down Steel Tubing 15mm Bore and Removing From Site All as Specified and Directed. , Taking Up Or Down Steel Tubing 25mm Bore and Removing From Site All as Specified and Directed. , Taking Down Eaves Gutters and Rain Water Pipes (any Size 75mm to 110mm of Any Pattern) , of Any Description and in Any Position, Including All Fittings , Heads, Shoes, Bends, Swan Necks, Etc Complete All as Specified and Directed. , Surface Dressing N. Exc. 15cm Deep in Soft/dense Soil Complete All as Specified and Directed. , Excavating in Trenches, N Exc 1.5 M Wide and N Exc 1.5 M in Depth; for Foundation, Etc. Or for Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M on Plan and N Exc 1.5 M in Depth and Getting Out in Soft/loose Soil Complete All as Specified and Directed. , Excavating in Trenches N Exc 1.5 M Wide and Exc 1.5 M and N Exc 3.0 M in Depth; for Foundation, Etc. Or for Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M on Plan and N Exc 1.5 M in Depth and Getting Out in Soft/loose Soil Complete All as Specified and Directed. , Excavation Over Aeras, N.exc 1.5 M Deep and Getting Out in Soft/ Loose Soil Complete All as Specified and Directed. , Returning, Filling with Approved Earth Including Spreading, Levelling, Watering and Well Ramming in Layers Not Exc 25 Cm Complete All as Specified and Directed. , Removing Excavated Material Exc. 50m Upto 250 M and Depositing Where Directed at a Level N Exc. 1.5 M Above the Starting Point Complete All as Specified and Directed. , M&l for Plain Cement Concrete Type D-2 (148) Using 40mm Crushed Stone Aggregate as in Foundation Filling and Mass Concrete All as Specified and as Directed. , M&l Treating the Top Surface of Filled at the Rate of 5 Litres of Emulsion Per Sqm of Surface Area Complete All as Per Specified and Dirceted. , M&l Treating the Soil Under Plinth Protection at the Rate of 5 Litres of Emulsion Per Sqm of Surface Area Complete All as Per Specified and Directed. , M&l Treating the Soil Along with External Perimeter of Building at the Rate of 2.25 Litres of Emulsion Per Sqm of Surface Area Complete All as Per Specified and Directed. , Precast Elements Providing , Transportation , Fixing , Erection and Installations Etc Complete for Rcc Precast Elements of Min Strength of M25 Desgin Mix for Various Sizes Shapes and Steel , Including Mould Making, Providing and Fixing Reinforcement Steel, Casting with Required Admixtures, Demolding, Curing, Transportation, Storage, Erection at Site, Grout Filling Etc Complete, this Also Includes All Labour Wages for Each Stage, Machinery, Cranes to Lift at Place at Various Stages Etc Including Placement of Electrical Conduits and Switch Boxes as Per Drawing, Placement of Cpvc Pipes, Including Jointing Lips and Hooks, Grout Couplers If Required, Gi Corrugated Sheaths for Dowel Bars, Providing Dowel Bars as Per Design, Grouting the Joints Wherever Required, Or Welding Already Provided Jointing Steel Bars, Making Good the Joint with Laticrete Or Equivalent, Providing Flexible Conduit for Connection of Wall and Slab Conduit, Filling Concrete in the Holes Kept for Jointing Electrical and Plumbing Pipes, Providing Required Cutouts for Sewerage and Other Pipes, Lifting and Fixing Arrangements, the Measurement of the Elements Shall Be Done in Full Without Deduction of Doors and Windows Cuts of Upto 2.5 Sqm Area, Including Vetting of Structural Drawings for Any Changes in the Structural Drawaing as Attached in List of Drawing for Precast Elements From Iit /nit Etc Complete All as Specified and Directed.
note Precast Rcc Concrete Element Shall Not Be Less Than M-30 Grade. the Design of Pre Cast Concrete Element (s) M-40 Grade Alongwith Architecture Design, Design Engineering, Structural Design Shall Be Provided By Bidder/contractor After Being Duly Ratified and Vetted By Indian Institute of Technology/ National Institute of Technology at No Additional Cost and Same Shall Be Approved By Accepting Officer. This Does Not Absolve the Contractor of His Responsibility of Rectification of Defects, Which May Arise at Later Stage. the Architecture Design, Design Engineering, Structural Design Duly Vetted By Iit/nit Shall Be Provided By the Contractor at No Additional Cost and Cost of the Same to Be Included in Quoted Amount. Work Shall Commence Only After Approval of Structural Drawings By Accepting Officer Which is Duly Vetted From Iit/nit. List of Drawings is Attached at Appx for Ref. However Final Structural Drawing Shall Be V
|